S.NO. | Name of Instrument and Make |
Instrument Serial No. | Capacity / Range | Least Count | Test Required | Calibration Status |
---|---|---|---|---|---|---|
1. | Tensile Testing Machine S.V Scientific Instrument |
506 | 500-N,1000N,2500N | 1-N ,2-N, 5-N | T.S.and Elongation of PVC,TS ofAllumin. | Yes |
2. | Double Kelvin Bridge with Galvanometer D.C. Source - Maxwell | 1790 | 0 to 11 ohms | 0.20 micro ohms | Annealing of copper Resistance of Conductor | Yes |
3. | Million Megaohm meter - Maxwell | 2928 | 1000x10*6 | 0.1Mega ohm | Insulation Resistance Volume | Yes |
4. | A.C.High Voltage Tester 22 KVA 100 AMP - REX | 0353 - 2k | 0.5 KV , 0.10 KV, | 0.1KV, 0.2KV | A.C.High Voltage | Yes |
5. | D.C.HighVoltage Tester - | 375 REX | 0to 3KV | 0.10KV | Water Immersion | Yes & Water |
6. | Spark Tester - REX | 565 | 0 to15 KV | 0.5 KV | Online Test | Yes |
7. | Ageing Oven - S.V. Scientific Inddustries |
1115067 | 0 to 400’c | 0.1’c | Ageing of PVC & Loss of Mass |
Yes |
8. | Universal Oven - S.v. Scientific Inddustries |
1111067 | 0 to 300’c | 0.1’c | Shrinkage & Hot Deformation Test | Yes |
9. | Hot Deformation Test - Appratus | 37106 | 1 to 800 grams | 1 gram | Hot Deformation | Yes |
10. | Chemical Balance - Dhona | 0 to 200 gram | 0.1 mg | Loss of Mass | Yes | |
11. | Water Bath with stirrer & Temp. Controller Arrangement - S.V. Scientific Inddustries |
0 to 200’c | 1’c | Water Immersion & Insulation Resistance | Yes | |
12. | Conditioning Chamber & Deep Freezer 50 ±5% (Relative Humidity) |
0to 20’c, 0 to 50..c | 0.1’c | Conditioning of PVC Compound | Self Caliberated | |
13. | Cold Impact Test | Cold Impact | Yes | |||
14. | Cold Bend Test Apparatus | Mandrells of Assorted size |
Cold Bend | Yes | ||
15. | Press & Dumb Bell Die - S.V. Scientific Inddustries |
Tensile Test | Yes | |||
16. | Thermal Stability Test - S.V. Scientific Inddustries |
23034 | 0 to 300’c | 0 - 10’c | Thermal of Compound | Yes |
17. | Travelling Micro Scope - Local | 10x | To measurement Thickness of Insulation & Sheath | Self Caliberated | ||
18. | Stop Watch - Casio | 2003 | 0.1 | Second For Time | - | |
19. | Heat Shock Test | Mandrells of Different size |
Heat Shock Sheath | Self Caliberated | ||
20. | Micrometer - Mitutoyo | 32719 | 0 to 25 mm | 0.001mm | Conductor Diameter | Yes |
21. | Vernier Calipers - Mitutoyo | 2569139 | 0 to 150 mm | 0.01 mm | Cable Dia Thickness | Yes |
22. | Flammaibility Test with Apparatus - Burner |
193 | 0 - 600 mm | Flammability Test of Cable |
Yes | |
23. | Standard Resistrance Box - Sigma | 0.001 ohm to 1 k ohm | to check Kelvin Bridge | Self Caliberated | ||
24. | Mega Ohms Box - Sigma | 3109 | 2M to 200M, 1G to 2G | To Check Million Mega Ohm Meter | Yes | |
25. | Electronics Balance | 0 - 15 kg. | 1 gram | Weight for Cable | Yes | |
26. | High Voltage Cage with Limit Switch Chainpully |
For High Voltage Test Drum Final Stage |
Yes | |||
27. | Thermal Meter - Gera | 250 | 0 - 110’c, 0 - 210’c | 01’c , 01’c | For Measurement of Temp. | Yes |
28. | Scale | 0 - 150, 0 - 300, 0 - 600 | 0.5 mm, 0.5mm, 0.5 mm | For Measurement | Yes | |
29. | Thermometer (Drij - Wet) Gera | 0 - 50’c | To mMeasure Tempo. | Yes | ||
30. | Water Tank For A.C. High Voltage Test for Single Core Unarmoured |